Products

PRODUCT CATEGORIES
Tension
S530S S-Beam Load Cell

S530S S-Beam Load Cell:

Product description:

S530S a round-shaped tension & compression load cell, completely hermetically sealed by laser to ensue it can work in harsh environments. Available in a wide range of capacities from 300kg thru to 5t


Main Features:

• Material: stainless steel

• Rated Capacities: 300kg~5t

• OIML R60, NTEP HB44, CE and RoHS certified

• IP Rating: IP66, IP68

• Suitable for process weighing of hopper scales, silo scales, tank scales.

• High precision by OIML R60 C3, high reliability.

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    ParameterUnitsSpecification
    Model No.
    S530S
    Rated capacity (Emax)t0.3; 0.5; 1; 2; 3; 5
    Min. dead loadkg0
    Rated outputmV/V2.0 ± 0.002
    Zero balance% of Emax± 1
    Combined error 1)2)% of Emax< ± 0.017
    Repeatability error% of AL 3) < ± 0.010
    Creep; 30 minute
    % of AL< ± 0.017
    Min. dead load output return (DR); 30 min
    % of AL< ± 0.017
    Temp. effect on
    Min. dead load output% of Emax/℃< ± 0.0023
    Rated output 2)% of AL/℃< ± 0.0020
    Temperature range
    Compensated℃(°F)
    -10 to +40 [+14 to +104]
    Operating-30 to +65 [-22 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltage
    RecommendedV AC/DC5 ~ 15
    Maximum15
    Terminal resistance
    ExcitationΩ
    382 ± 5
    Output350 ± 3
    Insulation resistance @50VDC>5000
    Breakdown voltage
    V AC>500
    Seal type / IP rating

    Cap. ≤1t: Silicon rubber / IP66

    Cap. ≥2t: Hermetically welded / IP68
    Load limit
    Safe% of Emax
    150
    Ultimate300
    Material
    Spring element
    Stainless steel
    Cable
    Φ5; 4-wire; PVC
    Cable length
    m3.0
    Weight; approx
    kg
    ≤0.5t1t2-5t
    0.70.92.0
    Fatigue life
    cycles @Emax>1,000,000
    Deflection at Emax; approx
    mm<0.5
    Barometric pressure effect on Zero Output
    Vmin/kPa<1.0
    Notes:
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load

    S530A-S-Beam-Load-Cell202206102005294248.jpg