Products

PRODUCT CATEGORIES
Double shear beam
DB916A Series Double-ended shear beam Load Cell

DB916A Series Double-ended shear beam Load Cell:

Product description:

DB916A is a double ended shear beam, both ends loaded, center supported via self-aligning column structure, so that the force can be applied properly. This load cell is suitable for a wide range of truck scales, rail scales and process weighing equipment of tank, bin and hopper scale, etc. It is bolted at both ends.. Fully alloy steel construct, hermetically sealed, which ensure high seals performance of waterproof.


Main Features:

• Material: Alloy steel

• Rated Capacities: 2.5klb~100klb

• IP Rating: IP68

• Suitable for truck scale, heavy duty hopper scale and other electronic weighing devices.

• High precision by NTEP III L 10000, high reliability.

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    PatameterUnitsSpecifications
    Model No.
    DB916A
    Rated capacity (Emax)klb2.5 / 5 / 10 / 20 / 35 / 50 / 75 / 100
    Accruacy class 1)2)
    0.03%
    Min. dead loadIb0
    Rated outputmV/V3.0 ± 0.003
    Zero balance% of Emax± 1
    Repeatability error% of AL 3)< ± 0.010
    Creep; 30 minute% of AL< ± 0.020
    Min. dead load output return (DR); 30 min% of AL< ± 0.020
    Temp. effect onMin. dead load output% of Emax/℃< ± 0.0014
    Rated output 2)% of AL/℃< ± 0.0012
    Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
    Operating-40 to +65 [-40 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC5 ~ 15
    Maximum20
    Terminal resistanceExcitationΩ766 ± 10
    Output700 ± 3
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    Seal type / IP rating
    Hermetically welded / IP68
    Load limitSafe % of Emax140
    Ultimate200
    MaterialSpring element
    Alloy steel nickel plated
    Cable
    Φ6; 4-wire; PVC
    Cable lengthm2.5-5klb10-35klb50-75klb; 100klb
    6.012.016.0
    Weight; approxlb2.5-5klb10-35klb50-100K
    4.07.025;50
    Fatigue lifecycles @Emax>1,000,000
    Deflection at Emax; approxmm<1.5
    Barometric pressure effect on Zero OutputVmin/kPa<1.0
    Notes:
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load


    DB916尺寸.jpg