Products

PRODUCT CATEGORIES
Double shear beam
DB940A Series Double-ended shear beam Load Cell

DB940A Series Double-ended shear beam Load Cell:

Product description:

DB940A is a double ended shear beam, both ends loaded, center supported via self-aligning semicircular arc convex structure, so that the force can be applied properly. This load cell is suitable for a wide range of truck scales, giant vessel scales and rail scales. It is designed to be lifted via a pair of parallel connected ring at both ends. Fully alloy steel construct, hermetically sealed, which ensure high seals performance of waterproof.


Main Features:

• Material: Alloy steel

• Rated Capacities: 25klb~100klb

• OIML NTEP HB44, CE and RoHS certified

• IP Rating: IP68

• Suitable for truck scale, heavy duty hopper scales and other electronic weighing devices.

• High precision by NTEP III L 10000, high reliability.

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    PatameterUnitsSpecifications
    Model No.
    DB940A
    Rated capacity (Emax)Ibs25K / 40K / 50K / 75K / 100K
    Accruacy class 1)2)% of Emax± 0.02
    Min. dead loadIb0
    Rated outputmV/V3.0 ± 0.1%
    Zero balance% of Emax± 1
    Repeatability error% of AL 3)< ± 0.05
    Creep; 30 minute% of AL < ± 0.02
    Min. dead load output return (DR); 30 min% of AL< ± 0.02
    Temp. effect onMin. dead load output% of Emax/℃< ± 0.002
    Rated output 2)% of AL/℃< ± 0.002
    Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
    Operating-40 to +65 [-40 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC5 ~ 15
    Maximum20
    Terminal resistanceExcitationΩ766 ± 10
    Output700 ± 3
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    Seal type / IP rating
    Hermetically welded / IP68
    Load limitSafe % of Emax150
    Ultimate200
    MaterialSpring element
    Alloy steel nickel plated
    Cable
    Φ6; 4-wire; PVC
    Cable length ft52.5 
    Weight; approxlb25-40K50-75K100K
    12.018.040.0
    Fatigue lifecycles @Emax>1,000,000
    Deflection at Emax; approxmm<1.5
    Notes:
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load


    DB940尺寸.jpg