Products

PRODUCT CATEGORIES
Canister Compression
P580SD/P780SD Canister Compression Load Cell

P580SD/P780SD Canister Compression Load Cell:

Product description:

The P580SD is a high-class digital canister compression load cell with double-cut faces against rotation. The P580SD is fully hermetically sealed with stamped integrated canister; which enable it to work in the harshest conditions. A rocker column design ensures optimum weighing accuracy when subjected to off-center and side forces when the scale deck is moving back and forth, meanwhile left and right.


Main Features:

• Material: Stainless steel

• Rated Capacities: 20t~50t

• 2pcs separate pluggable connectors, self-locked assembly, daisy connection without junction box.

• Advanced quick Protocol CANopen

• IP Rating: IP68, IP69K

• Suitable for truck scales, heavy duty hopper scales, force measurement equipment.

• OIML R60, NTEP HB44, CPA, CE and RoHS certified

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    ParameterUnitsSpecification
    Model No.
    P580SD / P780SD
    Load cell type
    Column Compression, Didital Weight Processor (DWP) 
    Rated capacity (R.C.)4)t20304050
    Sensitivity at R.C.d @ R.C.4)200,000300,000400,000500,000
    Communication
    Controller Area Network (CAN),   Encrypted
    Communication ratekbit/sec125
    Accuracy class
    C3             C4              C6
    Min. dead loadkg50
    Zero balancemV/V2.0 ± 0.002
    Y-value% of Emax± 1
    Repeatability error% of AL 3)< ± 0.010                  < ± 0.007                  < ± 0.005
    Creep; 30 minute% of AL< ± 0.0167                < ± 0.0125                  < ± 0.0083
    Min. dead load output return (DR); 30 min% of AL< ± 0.0167                  < ± 0.0125                  < ± 0.0083
    Temp.effect onMin. dead load output% of Emax/℃< ± 0.0018                  < ± 0.0014                  < ± 0.007
    Rated output 1)2)% of AL/℃< ± 0.00117                  < ± 0.0009                  < ± 0.006
    Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
    Operating-40 to +65 [-40 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC12 or 24
    Minimum / Maximum7.5 / 28
    Lightning protectionA>80,000
    Surge protective device
    Integral
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    ProtectionType
    Hermetically welded (submersible)
    IP rating
    IP68/69K [P780SD: Built-in Helium Sensor]
    Load limitSafe dynamic load% of Emax70
    Safe 200
    Ultimate300
    MaterialSpring element
    Stainless steel [P780SD: 17-4 PH]
    Enclosure
    304 stainless steel,  laser welded
    Anti-Rotation
    Integral; Parallel dual-plane
    Connectors
    Quick-Connect with bayonet lock, 5 Pins,Glass-to-Metal seal
    Strain gauge
    PEEK-1000 [P780SD: HBK]
    Cable construction

    Exterior braided armor covered with fireretardant TPU; PVC chemically 

    resistant jacket, 9mm O.D. ; 5 Conductors triple shielded and dual drain wires

    Cable lengthcell to cellm7 (Typical)
    home runm20 (Typical)
    Network
    No junction boxes
    Weight; approxkg6.0
    Fatigue lifecycles @Emax>1,000,000
    Deflection at Emax; approxmm<0.4<0.5<0.6<0.7
    Barometric pressure effect on Zero OutputVmin/kPa<1.0
    Notes: 
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load
    4) R.C. = Rated Capacity


    P580SD尺寸.jpg