Products

PRODUCT CATEGORIES
Tension
S515 Series S-Beam Load Cell

S515 Series S-Beam Load Cell:

Product description:

S515 is a square-shaped tension & compression load cell, high-quality silica gel potting is to ensure it can work in harsh environment. Available in a wide range of capacities from 1KN to 10KN


Main Features:

• Material: Alloy steel ( thread)

• Rated Capacity: 1KN~10KN

• Calibrated based on criterion of ISO 376

• IP Rating: IP66

• Suitable for force measurement and overloading safety controlling.

• High precision by ISO 376 class 0.5, 1, 2.

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    ParameterUnitsSpecification
    Model No.
    S515A
    Rated capacity (Emax)kN1 / 2 / 5 / 10
    Accruacy class 1)2)
    0.5                           00
    Min. dead loadN0
    Rated outputmV/V3.0 ± 0.003
    Zero balance% of Emax± 1
    Repeatability error% of AL 3) < ± 0.010                  < ± 0.006
    Creep; 30 minute% of AL< ± 0.017                  < ± 0.010
    Min. dead load output return (DR); 30 min% of AL< ± 0.017                  < ± 0.010
    Temp. effect onMin. dead load output% of Emax/℃< ± 0.0020                  < ± 0.0014
    Rated output 2)% of AL/℃< ± 0.0012                  < ± 0.0007
    Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
    Operating-40 to +65 [-40 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC5 ~ 15
    Maximum15
    Terminal resistanceExcitationΩ384 ± 5
    Output350 ± 3
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    Seal type / IP rating
    Silicon rubber / IP66
    Load limitSafe% of Emax140
    Ultimate200
    MaterialSpring element
    Alloy steel; Nickel plated
    Cable
    Φ5.6; 4-wire; PVC
    Cable lengthm5.0
    Weight; approxkg1-5 kN
    10 KIb
    0.8
    1.0
    Fatigue lifecycles @Emax>1,000,000
    Deflection at Emax; approxmm<1.0
    Barometric pressure effect on Zero OutputVmin/kPa<1.0
    Notes: 
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load


    S515尺寸.jpg