Products

PRODUCT CATEGORIES
Weigh Modules of Shear Beam
M-B510A-2A Weighing Module

M-B510A-2A Weighing Module:

Production description:

The M-B510A-2A is a typical weigh module assembled with B510A load cell, which is designed for dynamic weighing system, such as mixed hopper, silo, vessel and tank weighing systems. Capacity is from 0.5t to 25t. This module has 3 styles, fixed style, one-direction moving, free-moving with defined area, which are to avoid being stuck between upper plate and rocker pin during mixing inside.


Main Features:

• Compact and easy installation.

• Upper plate with blind hole to be loaded.

• Adjustable height screw against overload and overturn.

• Self-reset vertical force with rocker pin.

• Alloy steel and stainless steel optional.

• Assembled with single-ended shear beam B510A

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    Parameter UnitsSpecification
    Model No.
    M-B510A-2A
    Load Cell
    B510A
    Rated capacity (Emax)KIb1; 2.5; 4; 5SE4) ; 5; 10; 15; 20
    t0.5; 1; 2; 3; 5; 7.5; 10
    Rated outputmV/V3.0 ± 0.003
    Combined error 1)2)% of Emax< ± 0.017
    Repeatability error% of AL 3)< ± 0.010
    Creep; 30 minute% of AL< ± 0.017
    Min. dead load output return (DR); 30 min% of AL< ± 0.017
    Temp. effect onMin. dead load output% of Emax/℃< ± 0.0023
    Rated output 2)% of AL/℃< ± 0.0020
    Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
    Operating-30 to +65 [-22 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC5 ~ 15
    Maximum15
    Terminal resistanceExcitationΩ382 ± 5
    Output350 ± 3
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    Seal type / IP rating
    Hermetically welded / IP68
    Load limitSafe% of Emax150
    Ultimate200
    Cable lengthmCap. ≤2000kg/5000lb SE: 3.0
    Cap. ≥3000kg/5000lb: 5.0
    Notes:
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load
    4) SE = Small Edition

    M-B510A-2A-Weighing-Module202206101955056162.jpg