Products

PRODUCT CATEGORIES
Single Point
SP1041 Single-Point Load Cell

SP1041 Single-Point Load Cell:

Product description:

SP1041 is a typical and standard aluminum single point load cell that is compact, low capacity and ideal for a wide range of weighing equipment. Environmentally sealed with potting compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP1041 is suitable for new equipment manufacturer or as a replacement for existed weighing equipment.


Main Features:

• Material: Aluminum

• Rated Capacities: 10kg~100kg

• OIML R60, NTEP HB44, CPA, CE and RoHS certified

• IP Rating: IP66

• Suitable for pricing scales, counting scales, bench scales, etc.

• Max platform size: 400*400mm

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    ParameterUnitsSpecification
    Model No.
    SP1041
    Rated capacity (Emax)kg10 / 20 / 30 / 50 / 100
    Accuracy class
    C3                            C6
    Min. dead loadkg0
    Rated outputmV/V2.0 ± 0.2
    Zero balance% of Emax ± 2
    Repeatability error% of AL 3) < ± 0.010                    < ± 0.005
    Creep; 30 minute
    % of AL< ± 0.017                    < ± 0.0083
    Min. dead load output return (DR); 30 min
    % of AL< ± 0.017                    < ± 0.0083
    Temp. effect on
    Min. dead load output% of Emax/℃< ± 0.0020                    < ± 0.0014
    Rated output 2)% of AL/℃< ± 0.0012                    < ± 0.0006
    Temperature range
    Compensated℃(°F)
    -10 to +40 [+14 to +104]
    Operating-10 to +50 [+14 to +122]
    Safe storage-30 to +70 [-22 to +158]
    Excitation voltage
    RecommendedV AC/DC
    5 ~ 15
    Maximum15
    Terminal resistance
    ExcitationΩ
    403 ± 10
    Output350 ± 3
    Insulation resistance @50VDC
    >5000
    Breakdown voltage
    V AC>500
    Seal type / IP rating
    potted silicon sealed / IP66
    Load limit
    Safe% of Emax
    150
    Ultimate300
    Material
    Spring element
    Aluminum, anodizing
    Cable
    Φ5.6; 4-wire; PVC
    Cable length
    m2.0
    Maximum platform size
    mm400*400
    Offer center load error (OIML R76)
    % of AL/cm< ± 0.0028
    Fatigue life
    cycles@Emax>1,000,000
    Deflection at Emax; approx
    mm<0.5
    Weight; approx
    kg0.4
    Barometric pressure effect on Zero Output
    Vmin/kPa<1.0
    Mounting screw
    Size/Grade
    M6 / 8.8
    Recommended torqueN.m<50kg: 10;   ≥50kg: 15
    Notes:
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load


    SP1041尺寸.jpg