Products

PRODUCT CATEGORIES
Single Point
SP563S Single Point Load Cell

SP563S Single Point Load Cell:

Product description:

SP563S is a typical and standard stainless single point load cell that is high capacity and ideal for a wide range of weighing equipment. Hermetically sealing ensures reliability and durability. The industry standard size and mounting hole configuration makes the SP563S is suitable for new equipment manufacturer or as a replacement for existed weighing equipment.


Main Features:

• Material: stainless steel

• Rated Capacities: 100kg~750kg

• OIML R60, NTEP HB44, CPA, CE and RoHS certified

• IP Rating: IP68 / IP69K

• Environmentally sealed by potting special black glue, also strain gauge is double-sealed with another special nanoscale coating.

• Suitable for stainless steel waterproof scales, process weighing control in chemical, food and pharmaceutical industries.

• Max platform size: 300*350mm

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    PatameterUnitsSpecifications
    Model No.
    SP563S
    Rated capacity (Emax)kg100 / 200 / 300 / 500 / 750
    Accruacy class 1)2)
    C3                      C5
    Min. dead loadkg0
    Rated outputmV/V2.0 ± 0.2
    Zero balance% of Emax< ± 2
    Repeatability error% of AL 3) < ± 0.010                 < ± 0.006
    Creep; 30 minute% of AL< ± 0.017                 < ± 0.01
    Min. dead load output return (DR); 30 min% of AL< ± 0.017                 < ± 0.01
    Temp. effect onMin. dead load output% of Emax/℃< ± 0.0020                 < ± 0.0014
    Rated output 2)% of AL/℃< ± 0.0012                 < ± 0.0007
    Temperature rangeCompensated℃(°F)
    -10 to +40 [+14 to +104]
    Operating-40 to +65 [+40 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC
    5 ~ 15
    Maximum15
    Terminal resistanceExcitationΩ
    384 ± 5
    Output350 ± 3
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    Seal type / IP rating
    completely sealed hermectically / IP68 IP69k
    Load limitSafe % of Emax
    150
    Ultimate300
    MaterialSpring element
    stainless steel, electropolishing
    Cable connector
    stainless steel, electropolishing
    Cable
    Φ5.6; 4-wire; PVC
    Cable lengthm3.0
    Maximum platform sizemm600*600
    Offer center load error(OIML R76)% of AL/cm< ± 0.0019
    Weight; approxkg2.6
    Fatigue lifecycles @Emax>1,000,000
    Deflection at Emax; approxmm<0.5
    Barometric pressure effect on Zero OutputVmin/kPa<1.0
    Mounting screwSize/Grade
    M8 / 8.8
    Recommended torqueN.m30.0
    Notes:   
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load


    SP563尺寸.jpg