Products

PRODUCT CATEGORIES
Canister Compression
P520SD Canister Compression Load Cell

P520SD Canister Compression Load Cell:

Product description:

The P520SD is a typical digital high-precision canister compression load cell with double-cut faces against rotation. The P520SD is fully hermetically sealed with stamped integrated canister; which enable it to work in the harshest conditions. A rocker column design ensures optimum weighing accuracy when subjected to off-center and side forces when the scale deck is moving back and forth, meanwhile left and right.


Main Features:

• Material: Stainless steel

• Rated Capacities: 30t~50t

• Compensation mode: active compensation for non-linearity, creep, hysteresis, ZTC, STC, etc. 

• Advanced quick Protocol CANopen by 125 kbit/sec

• OIML R60, NTEP HB44, CPA, CE and RoHS certified

• IP Rating: IP68, IP69K

• Suitable for truck scales, heavy duty hopper scales, force measurement equipment.

• High precision by OIML R60 C6, high reliability

Contact
  • SPECIFICATIONS
  • DRAWING
  • DATA SHEET
  • APPROVALS
    ParameterUnitsSpecification
    Model No.
    P520SD
    Load cell type
    Column compression (Digital)
    Rated capacity (R.C.)4)t
    304050
    Sensitivity at R.C.d @ R.C.300,000400,000500,000
    Communication
    Controller Area Network (CAN),   Encrypted
    Communication ratekbit/sec125
    Accuracy class
    C3                     C4                     C6
    Min. dead loadkg50
    Zero balance% of Emax± 1
    Y-value
    10000                    12500                    20000
    Repeatability error% of AL 3)< ± 0.010           < ± 0.008             < ± 0.005
    Creep; 30 minute% of AL< ± 0.0167          < ± 0.0125           < ± 0.0083
    Min. dead load output return (DR); 30 min% of AL< ± 0.0167          < ± 0.0125           < ± 0.0083
    Temp.effect onMin. dead load output% of Emax/℃< ± 0.0016          < ± 0.00128         < ± 0.0008
    Rated output 1)2)% of AL/℃< ± 0.00133         < ± 0.0010          < ± 0.00066
    Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
    Operating-40 to +65 [-40 to +149]
    Safe storage-40 to +80 [-40 to +176]
    Excitation voltageRecommendedV AC/DC12 or 24
    Minimum / Maximum7.5 / 28
    Lightning protectionA>29,000
    Surge protective device
    Integral
    Insulation resistance @50VDC>5000
    Breakdown voltageV AC>500
    ProtectionType
    Hermetically welded 
    IP rating
    IP68/69K
    Load limitSafe dynamic load% of Emax70
    Safe 200
    Ultimate300
    MaterialSpring element
    Stainless steel
    Enclosure
    304 stainless steel,  laser welded
    Anti-Rotation
    Integral; Parallel dual-plane
    Connectors
    Integral
    Strain gauge
    PEEK-1000
    Cable construction

    Exterior braided armor covered with fireretardant TPU; PVC chemically 

    resistant jacket, 8mm O.D. ; 5 Conductors triple shielded wires

    CableCable lengthm16.0
    Network
    Junction boxes
    Weight; approxkg6.0
    Fatigue lifecycles @Emax>1,000,000
    Deflection at Emax; approxmm<0.5<0.6<0.7
    Barometric pressure effect on Zero OutputVmin/kPa<1.0
    Notes: 
    1) Error due to the combined effect of non-linearity and hysteresis
    2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
    3) AL = Applied Load
    4) R.C. = Rated Capacity


    P520S.jpg